COSHH Assessment · Pressure Washing & Jet Washing

COSHH Assessment for Pressure Washing & Jet Washing

A COSHH assessment of the hazardous substances used or created, built from the product's Safety Data Sheet (COSHH 2002). For pressure-washing operative, it has to cover high-pressure injection injuries. It must include each substance with its hazard statements and CAS number from the SDS. A common reason one is sent back: generic solvent boilerplate instead of the actual SDS hazards.

A COSHH assessment of the hazardous substances used or created, built from the product's Safety Data Sheet (COSHH 2002). Below: what a COSHH Assessment for pressure-washing operative must contain, why they get rejected, and the hazards it has to cover, or generate one for your exact job in a couple of minutes.

A finished example

Example COSHH Assessment from a similar trade (Cleaning Contractors)

We do not have a finished COSHH Assessment for pressure washing & jet washing yet, so this one is from cleaning contractors: the layout, scoring and sign-off are what yours needs, but the hazards and method will be different for your job.

The job it was written for: “Substances used and created during commercial, communal and post-construction cleaning. Commercial unit, occupied during working hours, 4 operatives, 4 days. Main risks: cleaning chemicals and cross-contamination; slips, trips and wet floors; working at height for high-level cleaning.”. Names and contact details are anonymised.

EXAMPLE

COSHH Assessment, Example Cleaning Contractor Ltd

Document TitleCOSHH Assessment
CompanyExample Cleaning Contractor Ltd
Site AddressUnit 4, Example Trading Estate, Exeter EX2 8XX
AssessorA. Supervisor
Date of Assessment14 October 2026
VersionV1.0
Review Date14 October 2027

1. Substances Assessed

This assessment is based on substance types common to this work. The Safety Data Sheet (SDS) for every specific product used on site must be obtained and its recommendations implemented. The site supervisor must ensure the SDS is available on site and briefed to operatives before use.

Product Type & Supplier (SDS §1)FormCLP Hazard Classification & H-Statements (from SDS §2)Hazardous Ingredient(s) & CAS No. (from SDS §3)Workplace Exposure Limit (WEL) (from SDS §8 / EH40/2005)
All-Purpose Cleaner / Surface SanitiserLiquidWarning: H315 Causes skin irritation. H319 Causes serious eye irritation.Surfactants, Quaternary ammonium compounds.No WEL assigned for the product as a mixture. Control exposure to As Low As Reasonably Practicable (ALARP).
Chlorine-based Cleaner / Disinfectant (e.g. Bleach)LiquidDanger: H314 Causes severe skin burns and eye damage. H335 May cause respiratory irritation. EUH031 Contact with acids liberates toxic gas.Sodium hypochlorite.No WEL assigned. The WEL for Chlorine gas is 0.5 ppm (STEL). Control exposure to ALARP.
Solvent-based Cleaner / Graffiti RemoverLiquid / AerosolDanger: H222 Extremely flammable aerosol. H315 Causes skin irritation. H319 Causes serious eye irritation. H336 May cause drowsiness or dizziness.Aliphatic / Aromatic hydrocarbons.Check SDS for specific ingredients and refer to EH40/2005 Workplace Exposure Limits. Control exposure to ALARP.

2. Process-Generated Substances

Substances created by the work process itself must also be controlled.

SubstanceProcess Creating ItHealth HazardWorkplace Exposure Limit (WEL) (from EH40/2005)
Respirable Crystalline Silica (RCS)Present in fine dust from concrete, brick, mortar, tiles during post-construction cleaning (sweeping, disturbing settled dust).Inhalation can cause silicosis, lung cancer, and other serious respiratory diseases. RCS is a carcinogen.WEL for Respirable Crystalline Silica: 0.1 mg/m³ (8-hour Time Weighted Average).
General airborne dust (low toxicity)Sweeping and cleaning of general settled dusts.Can cause irritation to eyes and respiratory system. May exacerbate pre-existing conditions like asthma.WEL for inhalable dust: 10 mg/m³ (8-hr TWA). WEL for respirable dust: 4 mg/m³ (8-hr TWA).

3. Who is Exposed and How?

  • Who is at risk: Cleaning operatives, other site workers, and members of the public in the vicinity.
  • Routes of Exposure:
    • Inhalation: Breathing in vapours from solvents, aerosols, dusts (especially RCS), or chlorine gas released by mixing chemicals.
    • Skin Absorption/Contact: Direct contact with liquid chemicals causing irritation, burns, or dermatitis. Splashes to skin or eyes.
    • Ingestion: Accidental swallowing of chemicals from contaminated hands.
  • Frequency and Duration: Exposure is intermittent over a 4-day period. Operatives may be exposed for several hours per day, depending on the specific task.

4. Risk Evaluation

Without controls, there is a High risk of skin/eye damage from corrosive or irritant chemicals. There is a High risk of long-term, irreversible lung disease from uncontrolled exposure to Respirable Crystalline Silica (RCS) during post-construction cleaning. Inhalation of solvent vapours presents a Medium risk of short-term health effects such as dizziness.

5. Control Measures

Controls must be implemented in accordance with the hierarchy specified in the Control of Substances Hazardous to Health Regulations 2002, Regulation 7. Personal Protective Equipment (PPE) is a last resort and must be used in addition to other controls.

Control Hierarchy (COSHH Reg 7)Recommended Control Measures, Confirm/Implement on SiteCompleted, Date & Initials
(a) Prevention / Elimination / Substitution1. Use the least hazardous cleaning product that is effective for the task. For example, use pH-neutral cleaners instead of harsh acids or alkalis where possible.
2. Design cleaning schedules to minimise dust creation. Use wet or damp cleaning methods instead of dry sweeping, especially for post-construction dust containing silica.
(b) Engineering Controls3. Ensure good natural ventilation in all work areas by opening windows and doors.
4. If ventilation is poor and solvent vapours or dusts are significant, use portable mechanical ventilation units to increase air changes.
5. For significant dust generation (post-construction), use an M-Class or H-Class rated vacuum cleaner with HEPA filtration for dust extraction at source. Do not use a domestic vacuum cleaner.
(c) Organisational / Administrative Controls6. NEVER mix cleaning chemicals, especially bleach-based products with any other cleaner, particularly acid-based products, to prevent release of toxic chlorine gas.
7. Decant chemicals only in well-ventilated areas. Ensure all containers are correctly labelled. Never use food or drink containers.
8. Restrict access to areas where cleaning chemicals are being used. Use warning signs (e.g., 'Cleaning in Progress', 'Wet Floor').
9. Provide welfare facilities with hot and cold running water, soap, and towels to allow operatives to wash hands before breaks and after work.
(d) Personal Protective Equipment (PPE)10. Gloves: Wear chemical-resistant gloves (e.g., nitrile, BS EN 374) appropriate to the chemicals being used, as specified in the product SDS.
11. Eye Protection: Wear safety goggles (BS EN 166) to protect against splashes when decanting or using liquid chemicals.
12. Respiratory Protective Equipment (RPE): For tasks creating significant dust (e.g., post-construction clean-up), an FFP3 disposable mask (BS EN 149) or half-mask respirator with P3 filters must be worn. All users of tight-fitting RPE must be face-fit tested.

6. Exposure vs WEL

With the above controls fully implemented, exposure to hazardous substances is not expected to exceed the Workplace Exposure Limits (WELs). For substances like RCS which are carcinogens, exposure must be reduced to as low as is reasonably practicable, not just below the WEL.

7. First Aid

  • Eyes: Immediately flush with copious amounts of clean, running water for at least 15 minutes. Seek immediate medical attention.
  • Skin: Remove contaminated clothing. Wash affected area thoroughly with soap and water. Seek medical advice if irritation persists. For chemical burns, seek immediate medical attention.
  • Inhalation: Move the affected person to fresh air. If they feel unwell, seek medical attention.
  • Ingestion: Do NOT induce vomiting. Wash out mouth with water. Seek immediate medical attention and show the product container or SDS.
  • A suitably stocked first-aid kit and an appointed person must be available on site.

8. Spillage and Accidental Release

  • In the event of a spillage, evacuate non-essential personnel and ventilate the area.
  • Contain the spill using absorbent granules or pads. Prevent entry into drains or watercourses.
  • Wear appropriate PPE (gloves, goggles, RPE if required) during clean-up.
  • Collect waste into a suitable, labelled container for disposal.

9. Handling, Storage, and Disposal

  • Handling: Follow instructions on the SDS. Avoid splashes and creation of vapours or dust.
  • Storage: Store chemicals in their original, correctly labelled containers in a cool, dry, well-ventilated area, away from incompatible materials (e.g., acids and bleach). Store securely to prevent unauthorised access.
  • Disposal: Dispose of waste chemicals and contaminated materials via a licensed waste contractor, in accordance with the product SDS and environmental regulations.

10. Health Surveillance

No specific health surveillance is required for this scope of work, provided the controls are fully implemented. However, any reported skin irritation or respiratory symptoms must be investigated by the supervisor.

11. Information, Instruction, and Training

All operatives must be trained on:

  • The findings of this COSHH assessment and the specific hazards of the chemicals in use.
  • How to read and understand a Safety Data Sheet (SDS).
  • The correct use, maintenance, and storage of control measures and PPE/RPE.
  • Emergency procedures for spillage and first aid.
  • The health risks associated with Respirable Crystalline Silica (RCS).

12. Review

This assessment must be reviewed by the date shown in the document control section, or immediately if:

  • There is a significant change in the work process or substances used.
  • Monitoring shows that control measures are inadequate.
  • An incident occurs related to substance exposure.

Declaration and Sign-off

The responsible person confirms that the recommended control measures listed in Section 5 have been implemented, are maintained, and are in use.

NameRoleSignatureDate
Supervisor

What a compliant COSHH Assessment must contain

  • Each substance with its hazard statements and CAS number from the SDS
  • The Workplace Exposure Limit (EH40) where one exists, never invented
  • Controls in order of effectiveness, LEV and ventilation before RPE (COSHH 2002)
  • Process-generated substances screened (dust, fume, silica)

Why a COSHH Assessment for pressure-washing operative gets rejected

  • Generic solvent boilerplate instead of the actual SDS hazards
  • A Workplace Exposure Limit fabricated for a substance that has none
  • Exposure risk credited mainly to gloves/masks (RPE is the LAST resort)
  • Process dust/fume (wood dust, welding fume, RCS) not assessed

Already have one? Check it against the standard, free.

Paste it below and it is scored the way an inspector would, with the failings that would get it rejected. No sign-up.

Pressure Washing & Jet Washing hazards it must cover

Pressure-washing operative, meaning cleaning driveways, render, roofs, plant and commercial premises with high-pressure water, brings hazards a COSHH Assessment has to address:

  • high-pressure injection injuries
  • slips on wet and algae-covered surfaces
  • working at height on roofs and render
  • chemical exposure from cleaning agents and biocides
  • noise from petrol machines

Generate your COSHH Assessment in minutes

Built to the correct published standard for pressure-washing operative: specific controls, the right legal basis, a review date and a sign-off section you can operate.

Start your COSHH Assessment

FAQ

Do you need a COSHH Assessment for pressure-washing operative?

A COSHH assessment of the hazardous substances used or created, built from the product's Safety Data Sheet (COSHH 2002). For pressure-washing operative, meaning cleaning driveways, render, roofs, plant and commercial premises with high-pressure water, it is the document a client, principal contractor or inspector expects to see, grounded in COSHH 2002 reg 6/7 (HSE), built from the product Safety Data Sheet.

What must a COSHH Assessment for pressure-washing operative contain?

At minimum: each substance with its hazard statements and CAS number from the SDS; the Workplace Exposure Limit (EH40) where one exists, never invented; controls in order of effectiveness, LEV and ventilation before RPE (COSHH 2002); process-generated substances screened (dust, fume, silica).

Why does a COSHH Assessment for pressure-washing operative get rejected?

The usual reasons: generic solvent boilerplate instead of the actual SDS hazards; A Workplace Exposure Limit fabricated for a substance that has none; exposure risk credited mainly to gloves/masks (RPE is the LAST resort); process dust/fume (wood dust, welding fume, RCS) not assessed.

Which regulation is a COSHH Assessment for pressure-washing operative written under?

COSHH 2002. The full text is on legislation.gov.uk at https://www.legislation.gov.uk/uksi/2002/2677/contents.

How fast can I get a COSHH Assessment?

A couple of minutes. Describe the job, and RAMSReady writes a COSHH Assessment for your exact pressure-washing operative live against the correct standard, with a review date and a sign-off/records section.

Not writing this one today?

We will email you a one page overview of what RAMSReady covers, so you have it when you need it.

Want to see how it would work for your firm?

Tell us roughly what you run and who keeps your records, and we will come back to you.

Related guides

Other documents for Pressure Washing & Jet Washing

Similar work

Templates and tools