RAMS · Tilers
RAMS for Tilers
A combined Risk Assessment & Method Statement, the site-ready document a principal contractor or client asks for before you start. For tiler work, it has to cover silica dust from cutting tiles (RCS, a carcinogen). It must include A hazard table with a likelihood × severity score before and after controls.
A combined Risk Assessment & Method Statement, the site-ready document a principal contractor or client asks for before you start. Below: what a tiler's RAMS must contain, why they get rejected, and the hazards it has to cover, or generate one for your exact job in a couple of minutes.
A finished example
Example RAMS from a similar trade (Flooring Contractors)
We do not have a finished RAMS for tilers yet, so this one is from flooring contractors: the layout, scoring and sign-off are what yours needs, but the hazards and method will be different for your job.
The job it was written for: “Job: floor prep, screeding, tiling and floor-covering installation. Commercial unit, occupied during working hours, 3 operatives, 3 days. Main risks: adhesives, resins and solvents; silica dust from grinding/screed; manual handling and kneeling.”. Names and contact details are anonymised.
RAMS (Risk Assessment & Method Statement), Example Flooring Contractor Ltd
| Field | Detail |
|---|---|
| Document Title | Risk Assessment & Method Statement: Floor Preparation & Installation |
| Company | Example Flooring Contractor Ltd |
| Author | A. Supervisor |
| Date | 14 October 2026 |
| Version | V1.0 |
| Review Date | 14 October 2027 |
Company details
| Field | Detail |
|---|---|
| Company name | Example Flooring Contractor Ltd |
| Address | to be confirmed |
| Registration number | to be confirmed |
| Phone | 01283 000000 |
| Named supervisor | A. Supervisor |
| Insurance valid until | to be confirmed |
Project / Job information
| Field | Detail |
|---|---|
| Site address | Unit 4, Example Trading Estate, Exeter EX2 8XX |
| Client | Example Client |
| Start date | 14 October 2026 |
| Expected duration | 3 days |
Scope of works
This document covers the safe systems of work for the preparation of existing concrete floors and the installation of new floor coverings (screed, tiles, vinyl) within an occupied commercial unit.
The work sequence includes:
- Site set-up, including establishment of cordoned work areas.
- Mechanical preparation of the concrete substrate using floor grinders with dust extraction.
- Application of self-levelling screed compounds.
- Laying of specified floor coverings using adhesives, resins and solvents.
- Cutting and fitting of floor coverings.
- Site clean-down and removal of waste materials.
Hazard identification
This risk assessment is completed under the Management of Health and Safety at Work Regulations 1999 (MHSWR). It records the significant findings of the assessment. The responsible person must confirm that all control measures are in place before work starts.
| HAZARD | RISK / WORST-CASE OUTCOME | WHO IS AT RISK | RISK BEFORE CONTROLS: L × S = Score (Rating) | CONTROL MEASURES (in hierarchy order) | RISK AFTER CONTROLS: L × S = Score (Rating) |
|---|---|---|---|---|---|
| Presence of asbestos containing materials (ACMs) in existing floor tiles or adhesive residues. | Uncontrolled release of asbestos fibres leading to inhalation. Potentially fatal lung diseases (mesothelioma, asbestosis) with long latency. | Operatives, site staff, public. | 5 × 5 = 25 (Very High) | ⛔ STOP, CONFIRM AT SITE SURVEY:<br>1. Asbestos Survey: Before any work that may disturb the building fabric, an asbestos refurbishment survey must be obtained from the client, as required by the Control of Asbestos Regulations 2012.<br>2. Confirm Absence: Work must not proceed until the survey confirms no ACMs are present in the work area or materials to be disturbed.<br>3. Licensed Removal: If ACMs are found, they must be removed by a licensed asbestos contractor under controlled conditions before flooring work commences. This RAMS does not cover asbestos removal. | 2 × 5 = 10 (High) |
| Manual handling of heavy/awkward items (rolls of flooring, bags of screed, buckets of adhesive, equipment). | Musculoskeletal injuries (sprains, strains), particularly to the back, shoulders and knees. Dropped loads causing crush injuries to feet. | Operatives. | 4 × 3 = 12 (High) | 1. Reduce Load: Procure materials in smaller, manageable weights where possible (e.g., 20kg bags instead of 25kg).<br>2. Mechanical Aids: Use trolleys or sack barrows for moving materials from delivery point to work area.<br>3. Team Lifting: For items over 20kg or for awkward loads, a minimum two-person lift must be used.<br>4. Training: All operatives are trained in correct kinetic lifting techniques.<br>5. PPE: Wear steel toe-capped safety boots (BS EN ISO 20345). | 2 × 3 = 6 (Medium) |
| Exposure to respirable crystalline silica (RCS) dust from grinding concrete floors or mixing powdered screed. | Inhalation of fine silica dust leading to silicosis, lung cancer and chronic obstructive pulmonary disease (COPD). | Operatives, site staff, public. | 5 × 4 = 20 (Very High) | 1. Engineering Controls (LEV): All floor grinding equipment must be fitted with an M-class or H-class vacuum extractor at the source. Ensure correct filter class and efficient extraction.<br>2. Dampening: Dampen down powdered screeds during mixing to suppress dust.<br>3. Segregation: Cordon off the immediate work area to prevent entry by non-essential personnel during dust-generating tasks.<br>4. RPE: Wear FFP3 disposable masks or a half-mask respirator with P3 filters (BS EN 149) during all dust-generating activities.<br>5. Health Surveillance: Operatives to be under health surveillance for RCS exposure as per company policy. | 2 × 4 = 8 (Medium) |
| Exposure to hazardous substances (adhesives, resins, solvents, primers). | Skin contact causing dermatitis or burns. Inhalation of vapours causing dizziness, headaches, respiratory irritation, or long-term health effects. | Operatives, site staff. | 4 × 3 = 12 (High) | 1. Ventilation: Ensure good natural or mechanical ventilation in the work area at all times.<br>2. COSHH: Adhere strictly to controls outlined in the COSHH assessments. Do not mix incompatible substances.<br>3. PPE: Wear chemical-resistant gloves (BS EN 374) and eye protection (BS EN 166). If specified by the COSHH assessment, wear vapour-filter respiratory protection.<br>4. Hygiene: Wash hands before eating, drinking or smoking. Use provided skin cleansers. | 2 × 3 = 6 (Medium) |
| Slips, trips and falls on same level due to tools, materials, waste, trailing cables or wet surfaces (adhesives, screed). | Fractures, sprains, bruises, head injuries. | Operatives, site staff, public. | 4 × 3 = 12 (High) | 1. Housekeeping: Maintain a high standard of housekeeping. Keep work areas clear of obstructions and waste. Designate a lay-down area for tools and materials.<br>2. Cable Management: Use cordless tools where possible. Route any necessary cables away from walkways. Use cable covers.<br>3. Signage: Use 'Wet Floor' signs where adhesives or screeds have been applied.<br>4. Spills: Clean up any spills immediately. | 2 × 3 = 6 (Medium) |
| Noise exposure from floor grinding equipment. | Noise-induced hearing loss (NIHL), tinnitus. | Operatives, nearby site staff. | 4 × 3 = 12 (High) | 1. Equipment Selection: Use modern, well-maintained equipment specified as low-noise where possible.<br>2. Limiting Exposure: Rotate tasks to limit individual exposure time.<br>3. Segregation: Cordon off the work area to prevent others being exposed to high noise levels.<br>4. PPE: Wear suitable hearing protection (ear defenders or plugs, BS EN 352) in designated hearing protection zones. | 2 × 3 = 6 (Medium) |
| Musculoskeletal strain from prolonged kneeling and awkward postures during floor laying. | Chronic pain in knees, back and neck. Conditions such as bursitis ('beat knee'). | Operatives. | 4 × 3 = 12 (High) | 1. Work Planning: Ensure sufficient space to work comfortably. Rotate tasks between operatives to vary posture.<br>2. PPE: Provide and ensure use of high-quality knee pads designed for flooring work.<br>3. Breaks: Encourage operatives to take regular short breaks to stretch and change position. | 2 × 3 = 6 (Medium) |
| Use of electrical equipment (110V floor grinder, mixers, etc). | Electric shock, burns, fire, potentially fatal. | Operatives. | 3 × 4 = 12 (High) | 1. Equipment: Use 110V equipment powered via a transformer with correctly rated industrial plugs and sockets. All equipment to be PAT tested and in good condition.<br>2. Inspection: Visually inspect all tools, cables and connections for damage before each use.<br>3. Cables: Do not run cables through water or where they can be damaged by traffic.<br>4. Isolation: Do not attempt repairs on live equipment. Isolate from power first. | 2 × 4 = 8 (Medium) |
| Contact with sharps (utility knives, Stanley blades, exposed sub-floor fixings). | Lacerations, cuts, puncture wounds, potential for infection. | Operatives. | 3 × 3 = 9 (Medium) | 1. Safe Use: Use knives with retractable or self-retracting blades. Always cut away from the body.<br>2. Blade Disposal: Use a sharps container for disposal of used blades.<br>3. PPE: Wear cut-resistant gloves (BS EN 388) when using knives or handling materials with sharp edges. | 2 × 3 = 6 (Medium) |
Method statement
All operatives will receive a briefing on this RAMS before work begins. Work will be conducted in a controlled and segregated area to minimise disruption to the occupied premises.
1. Pre-start and site setup
- On arrival, report to the client representative. Confirm work area, access routes, welfare facilities and emergency procedures.
- Review the asbestos register for the building. Confirm with the client that no asbestos-containing materials will be disturbed. Work must not start if this confirmation is not available.
- Cordon off the immediate work area using barriers and warning signs to prevent unauthorised access, particularly by building occupants.
- Set up a designated waste area for offcuts and packaging.
- Visually inspect all power tools, extension leads and transformers before use. Ensure PAT test dates are valid.
- Set up a 110V transformer at a designated, safe supply point.
2. Floor preparation
- Put on all required PPE for dust generation: FFP3 mask, safety glasses, hearing protection, safety boots and gloves.
- Connect an M-class (or H-class) dust extractor to the floor grinder. Ensure hoses are secure and the extractor filter is clean.
- Commence grinding of the concrete substrate. Work systematically across the area, ensuring the extraction shroud remains in contact with the floor.
- Once grinding is complete, vacuum the entire area thoroughly using the M/H-class extractor to remove all residual dust.
- Bag all collected dust carefully, seal the bags, and label them as silica dust waste for correct disposal.
3. Application of screed and adhesives
- Ensure the area is well-ventilated by opening doors and windows where possible.
- Put on required PPE: chemical-resistant gloves and safety glasses.
- Mix screed or adhesives according to the manufacturer's instructions. Add powder to water slowly to minimise dust creation.
- Apply the product to the floor using trowels or spreaders. Work from the furthest point back towards the exit.
- Display 'Wet Floor' signs at all entry points to the screeded/glued area.
- Allow material to cure for the manufacturer's recommended time before proceeding.
4. Installation of floor coverings
- Move materials to the work area using trolleys or team lifting as required.
- Measure and cut flooring materials using appropriate tools (e.g., utility knives with retractable blades).
- Ensure operatives wear knee pads when kneeling for prolonged periods.
- Lay the floor covering onto the prepared surface, ensuring a firm bond.
- Clean any excess adhesive from the surface and tools as you work, using the recommended solvent and cloths.
5. Completion and clean-up
- Collect all waste materials, offcuts, and packaging. Segregate for correct disposal.
- Clean the work area, leaving it in a safe and tidy condition.
- Inspect the finished work with the client representative.
- Remove all barriers, signs, tools and equipment from the site.
Hazardous substances used
A full COSHH assessment for each substance must be available on site. All controls identified in the assessments must be implemented.
| Substance | Where used | Hazard | Controls | COSHH assessment ref. |
|---|---|---|---|---|
| Respirable Crystalline Silica (RCS) Dust | Floor grinding, mixing screed | Carcinogenic, causes silicosis | On-tool dust extraction (LEV), RPE (FFP3), dampening, health surveillance. | COSHH-1 (generate) |
| Cement-based screed powder | Floor levelling | Skin/eye irritant, respiratory irritant | PPE (gloves, goggles, RPE), dampening during mixing, good hygiene. | COSHH-2 (generate) |
| Floor adhesives (e.g., epoxy resin) | Securing floor coverings | Skin/eye irritant, sensitiser, harmful vapours | Ventilation, chemical-resistant gloves, eye protection, good hygiene. | COSHH-3 (generate) |
| Solvents / cleaning fluids | Cleaning tools and surfaces | Flammable, skin/eye irritant, harmful vapours | Ventilation, no ignition sources, gloves, eye protection, correct storage. | COSHH-4 (generate) |
Competence and training
| Role | Required competence (cards, tickets, training) | Evidence held |
|---|---|---|
| All operatives | CSCS card (Flooring or relevant trade) | to be confirmed by Example Flooring Contractor Ltd |
| All operatives | Site induction (provided by client) | to be confirmed by Example Flooring Contractor Ltd |
| All operatives | Manual handling awareness training | to be confirmed by Example Flooring Contractor Ltd |
| All operatives | Asbestos awareness training (UKATA Category A) | to be confirmed by Example Flooring Contractor Ltd |
| All operatives | Face-fit testing for tight-fitting RPE | to be confirmed by Example Flooring Contractor Ltd |
| Named first aider | First Aid at Work (FAW) certificate, in date | to be confirmed by Example Flooring Contractor Ltd |
PPE requirements
| Item | Standard |
|---|---|
| Head Protection | Not required for this scope of work |
| Eye Protection | Safety glasses / goggles to BS EN 166 |
| Hand Protection | Cut-resistant gloves (BS EN 388), Chemical-resistant gloves (BS EN 374) |
| Foot Protection | Safety boots with toe and midsole protection to BS EN ISO 20345 |
| High-Visibility Clothing | Not required for this internal scope of work |
| Respiratory Protection | FFP3 disposable mask or half-mask with P3 filters to BS EN 149 |
| Hearing Protection | Ear defenders or plugs to BS EN 352 |
| Other | Knee pads |
Emergency arrangements
| Item | Detail |
|---|---|
| Site First Aider | A. Supervisor (confirm before start on site) |
| First Aid Kit Location | In company vehicle |
| Nearest A&E | Royal Devon and Exeter Hospital, Exeter (confirm before start on site) |
| Fire Assembly Point | As designated by the client during site induction |
| Emergency Contact | A. Supervisor, 01283 000000 |
| Spill Procedure | Contain spill using spill kit granules from company vehicle. Ventilate area. Dispose of contaminated materials as hazardous waste. |
Rescue plan
Work at height is not anticipated for this scope of works, therefore no rescue plan is required.
Environmental considerations
- All waste will be segregated on site (general, mixed recycling, hazardous) and removed by a licensed waste carrier.
- Solvents and chemical containers will not be disposed of in general waste. They will be returned to the workshop for correct disposal.
- Measures will be taken to control dust and noise to minimise impact on the local environment and building occupants.
Risk matrix key & sign-off
Risk Matrix
| Likelihood | 1 (Very unlikely) | 2 (Unlikely) | 3 (Possible) | 4 (Likely) | 5 (Very likely) |
|---|---|---|---|---|---|
| 5 (Catastrophic) | 5 | 10 | 15 | 20 | 25 |
| 4 (Major) | 4 | 8 | 12 | 16 | 20 |
| 3 (Moderate) | 3 | 6 | 9 | 12 | 15 |
| 2 (Minor) | 2 | 4 | 6 | 8 | 10 |
| 1 (Insignificant) | 1 | 2 | 3 | 4 | 5 |
Ratings: 1-4: Low | 5-9: Medium | 10-15: High | 16-25: Very High
Operative briefing and sign-off
I confirm that I have read and understood the requirements of this Risk Assessment and Method Statement. I will comply with the specified control measures and safe systems of work. I am aware of my responsibilities under the Health and Safety at Work etc. Act 1974.
| Name | Signature | Date |
|---|---|---|
What a compliant RAMS must contain
- A hazard table with a likelihood × severity score before and after controls
- Controls in the correct hierarchy (eliminate → substitute → engineering → admin → PPE last)
- A numbered, step-by-step method statement for the actual task
- PPE to BS EN standards, emergency arrangements, and an operative sign-off
Why a tiler's RAMS gets rejected
- Residual risk dropped from high to low on PPE or 'competent operatives' alone
- Generic hazards that could apply to any job
- No method statement, or one too vague to follow on site
- The wrong legal basis cited, such as CDM 2015 named for work that is not construction
Already have one? Check it against the standard, free.
Paste it below and it is scored the way an inspector would, with the failings that would get it rejected. No sign-up.
Tilers hazards it must cover
Typical tiler work, meaning wall and floor tiling, wet-room tanking, screeding and grouting, brings hazards a RAMS has to address:
- silica dust from cutting tiles (RCS, a carcinogen)
- cement dermatitis and burns from adhesives and grout
- kneeling and repetitive strain
- noise and vibration from cutters and grinders
- slips on wet floors and spilt adhesive
Generate your RAMS in minutes
Built to the correct published standard for a tiler: specific controls, the right legal basis, a review date and a sign-off section you can operate.
Start your RAMSFAQ
Do tilers legally need a RAMS?
A combined Risk Assessment & Method Statement, the site-ready document a principal contractor or client asks for before you start. For tiler work, meaning wall and floor tiling, wet-room tanking, screeding and grouting, it is the document a client, principal contractor or inspector expects to see, grounded in MHSWR 1999 reg 3 (HSE): the combined risk assessment + method statement contractors submit.
What must a tiler's RAMS contain?
At minimum: A hazard table with a likelihood × severity score before and after controls; controls in the correct hierarchy (eliminate → substitute → engineering → admin → PPE last); A numbered, step-by-step method statement for the actual task; PPE to BS EN standards, emergency arrangements, and an operative sign-off.
Why does a tiler's RAMS get rejected?
The usual reasons: residual risk dropped from high to low on PPE or 'competent operatives' alone; generic hazards that could apply to any job; no method statement, or one too vague to follow on site; the wrong legal basis cited, such as CDM 2015 named for work that is not construction.
Which regulation is a tiler's RAMS written under?
MHSWR 1999. The full text is on legislation.gov.uk at https://www.legislation.gov.uk/uksi/1999/3242/contents.
How fast can I get a RAMS?
A couple of minutes. Describe the job, and RAMSReady writes a RAMS for your exact tiler job live against the correct standard, with a review date and a sign-off/records section.
Not writing this one today?
We will email you a one page overview of what RAMSReady covers, so you have it when you need it.
Want to see how it would work for your firm?
Tell us roughly what you run and who keeps your records, and we will come back to you.