COSHH Assessment · Commercial Catering Engineers

COSHH Assessment for Commercial Catering Engineers

A COSHH assessment of the hazardous substances used or created, built from the product's Safety Data Sheet (COSHH 2002). For commercial catering engineer work, it has to cover gas at work: uncontrolled release or ignition during work on commercial gas appliances. It must include each substance with its hazard statements and CAS number from the SDS.

A COSHH assessment of the hazardous substances used or created, built from the product's Safety Data Sheet (COSHH 2002). Below: what a commercial catering engineer's COSHH Assessment must contain, why they get rejected, and the hazards it has to cover, or generate one for your exact job in a couple of minutes.

A finished example

Example COSHH Assessment from a similar trade (Plumbing & Heating Engineers)

We do not have a finished COSHH Assessment for commercial catering engineers yet, so this one is from plumbing & heating engineers: the layout, scoring and sign-off are what yours needs, but the hazards and method will be different for your job.

The job it was written for: “Substances used and created during boiler, pipework, gas and heating installation and service. Commercial unit, occupied during working hours, 3 operatives, 3 days. Main risks: gas work; hot works and legionella; working at height and in confined spaces.”. Names and contact details are anonymised.

EXAMPLE

COSHH Assessment, Example Plumbing & Heating Engineer Ltd

Document TitleCOSHH Assessment: Boiler & Heating Systems Installation/Service
CompanyExample Plumbing & Heating Engineer Ltd
Site AddressUnit 4, Example Trading Estate, Exeter EX2 8XX
AssessorA. Supervisor
Date of Assessment14 October 2026
VersionV1.0
Review Date14 October 2027

1. Substances Assessed

This assessment is based on substances common to the plumbing and heating trade. The specific Safety Data Sheet (SDS) for each product being used on site MUST be obtained and reviewed before work begins. Controls must be adapted to the specific product data.

Product / SupplierFormHazard Classification & Statements (from SDS §2)Hazardous Ingredient(s) (CAS No.)Workplace Exposure Limit (WEL) from EH40/2005
PVC / ABS Solvent Cement (e.g. Polypipe, FloPlast)Liquid / VapourH225: Highly flammable liquid and vapour. H319: Causes serious eye irritation. H335: May cause respiratory irritation. H336: May cause drowsiness or dizziness. H351: Suspected of causing cancer.Tetrahydrofuran (109-99-9), Cyclohexanone (108-94-1), Butanone (MEK) (78-93-3)Butanone: LTEL 200 ppm, STEL 300 ppm. Cyclohexanone: LTEL 10 ppm, STEL 20 ppm. Tetrahydrofuran: LTEL 50 ppm, STEL 100 ppm.
Flux Paste (for soldering)PasteH314: Causes severe skin burns and eye damage. H317: May cause an allergic skin reaction. H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.Zinc Chloride (7646-85-7), Ammonium Chloride (12125-02-9)Zinc chloride fume: LTEL 1 mg/m³, STEL 2 mg/m³. Ammonium chloride fume: LTEL 10 mg/m³, STEL 20 mg/m³.
PTFE / Gas Sealant PastePasteGenerally low hazard. May contain hydrocarbons. H304: May be fatal if swallowed and enters airways.Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, < 2% aromaticsNo WEL assigned. Control to As Low As Reasonably Practicable (ALARP).
Silicone SealantPaste / VapourH317: May cause an allergic skin reaction. Releases methylethylketoxime or acetic acid during curing, which can irritate eyes and airways.Specific to product. May include methyl ethyl ketoxime (96-29-7).Acetic acid: LTEL 10 ppm, STEL 20 ppm. Control curing vapours to ALARP.
Leak Detection Fluid / SprayLiquid / AerosolGenerally low hazard. Propellant may be flammable.Propane (74-98-6), Butane (106-97-8)Butane: LTEL 600 ppm, STEL 750 ppm.

2. Process-Generated Substances

These hazardous substances are created by the work process itself.

SubstanceProcess Creating ItFormHazard Classification & StatementsHazardous Ingredient(s)Workplace Exposure Limit (WEL) from EH40/2005
Solder FumeSoldering copper pipework ('hot works').Fume (particulate)H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled. H317: May cause an allergic skin reaction. Fume contains rosin (colophony).Lead (where leaded solder is used, 7439-92-1), Rosin (Colophony) (8050-09-7)Rosin-based solder flux fume: LTEL 0.05 mg/m³, STEL 0.15 mg/m³. Inorganic lead: LTEL 0.15 mg/m³.
Natural Gas (Methane)Gas pipework installation and boiler commissioning / servicing. Accidental release from existing systems.GasH220: Extremely flammable gas. H280: Contains gas under pressure; may explode if heated. Asphyxiant in high concentrations.Methane (74-82-8), Ethane, Propane.Asphyxiant. No WEL assigned. Control to prevent flammable atmosphere and oxygen depletion.
Carbon Monoxide (CO)Incomplete combustion from poorly maintained or faulty gas appliances. Present during commissioning and servicing.GasH331: Toxic if inhaled. H360D: May damage the unborn child. H372: Causes damage to organs through prolonged or repeated exposure.Carbon Monoxide (630-08-0)LTEL 30 ppm, STEL 200 ppm.
Legionella bacteriaRelease of aerosol/water spray from stagnant or contaminated domestic hot/cold water systems during draining or modification.Biological AgentHazard Group 2. Can cause Legionnaires' disease, a potentially fatal form of pneumonia.Legionella pneumophilaNo WEL assigned. Prevent exposure to contaminated aerosols.
Products of Combustion (Flue Gases)Boiler servicing, commissioning and testing.Gas / VapourIncludes Carbon Monoxide, Carbon Dioxide, Nitrogen Oxides (NOx), Sulphur Dioxide (SO2). Irritant and toxic components.CO, CO2, NOx, SO2.CO: LTEL 30 ppm, STEL 200 ppm. CO2: LTEL 5000 ppm, STEL 15000 ppm. NO2: LTEL 0.5 ppm, STEL 1 ppm.
Dust from drilling/cuttingDrilling into walls (brick, block, plasterboard) for pipe and flue penetrations.DustMay contain Respirable Crystalline Silica (RCS) from masonry. H350: May cause cancer (silicosis, lung cancer). H372: Causes damage to lungs through prolonged or repeated exposure.Crystalline Silica (Quartz) (14808-60-7)Respirable Crystalline Silica (RCS): LTEL 0.1 mg/m³.

3. Who is Exposed and How?

Persons ExposedRoute(s) of ExposureFrequency & Duration of Exposure
Plumbing & Heating Engineers (3 operatives)Inhalation of vapours, fumes, dust, gases. Skin contact/absorption with solvents, pastes, sealants. Ingestion via contaminated hands. Injection from sharp pipework offcuts.Intermittent but repeated daily over a 3-day period. Short duration for tasks like soldering or solvent welding (minutes), longer for potential gas/CO exposure.
Client Staff / Other OccupantsInhalation of vapours, fumes, gases that may spread from the immediate work area.Low risk if work area is segregated and well-ventilated. Potential for brief exposure if they enter the work area.

4. Risk Evaluation

Without controls, there is a significant health risk.

  • Solder Fume & Flux: High risk of occupational asthma. Rosin (colophony) is a respiratory sensitiser.
  • Solvent Cement: High risk of narcotic effects (dizziness), respiratory and eye irritation from vapours in poorly ventilated areas. Long-term cancer risk is noted.
  • Carbon Monoxide & Natural Gas: Acute risk of poisoning, asphyxiation, fire, and explosion. This is a high-risk activity managed under the Gas Safe Register regime.
  • Legionella: High risk of fatal lung disease if contaminated aerosols are inhaled from stagnant water systems.
  • Silica Dust: High risk of incurable lung disease (silicosis) and cancer from uncontrolled drilling/cutting of masonry.

5. Control Measures (in accordance with COSHH Reg 7 hierarchy)

The responsible person must confirm these controls are in place and effective. An action plan for any outstanding items is provided below.

5a. Prevention, Elimination or Substitution

  1. Lead-free Solder: Use lead-free solder to eliminate exposure to lead fume.
  2. Rosin-free Flux: Where practicable, use rosin-free flux pastes to prevent exposure to this respiratory sensitiser.
  3. Push-fit Fittings: Use mechanical push-fit fittings instead of soldering or solvent welding where system specification allows, eliminating fume and vapour release.
  4. Low-VOC Products: Select solvent cements, sealants and cleaners with the lowest possible Volatile Organic Compound (VOC) content.

5b. Engineering Controls & Control at Source

  1. Ventilation: Ensure good general ventilation in the work area by opening windows and doors. For high-vapour tasks (solvent welding), use mechanical ventilation (fans) to create through-draught.
  2. Local Exhaust Ventilation (LEV):
    • For drilling/cutting masonry: Use on-tool extraction (M-class or H-class vacuum) attached directly to the tool's dust-shroud. This captures silica dust at source.
    • For soldering: Where ventilation is poor or soldering is prolonged, portable fume extraction with a flexible capture hood must be used.
  3. Water Suppression: Use water spray to dampen materials during cutting or drilling to suppress dust generation.
  4. Flue Gas Analysis: Use a calibrated Flue Gas Analyser for all boiler commissioning and servicing to directly measure combustion by-products (CO, CO2) and ensure safe appliance operation. This is a mandatory Gas Safe requirement.
  5. Personal CO Alarms: All operatives working on gas systems must wear a personal, calibrated Carbon Monoxide alarm.
  6. Gas Isolation: Physically isolate relevant gas pipework sections before starting work. Conduct tightness testing before and after work to prevent leaks.
  7. Legionella Control: Drain down systems safely. Minimise aerosol generation. If a system is known to be high-risk (e.g., long-disused), specific legionella controls and potential disinfection procedures are required before commencing work.

5c. Organisational / Administrative Controls

  1. Competence: All gas work to be carried out ONLY by Gas Safe Registered engineers with the correct qualifications for the appliances and pipework involved.
  2. Segregation: Cordon off the immediate work area to prevent entry by client staff, especially during high-hazard tasks like purging, soldering, or solvent welding. Use appropriate safety signage.
  3. Work Rotation: For prolonged tasks involving solvents, rotate operatives to reduce individual exposure times.
  4. Asbestos:
    • ⛔ STOP, CONFIRM AT SITE SURVEY: Before drilling or cutting into any building fabric (walls, floors, ceilings) or disturbing pipe lagging, the site's asbestos register MUST be consulted. If no register exists or is inconclusive, the materials must be presumed to contain asbestos. No intrusive work may proceed until this is resolved. Work on any presumed or confirmed Asbestos Containing Material (ACM) requires a specialist licensed contractor under the Control of Asbestos Regulations 2012.
  5. Confined Spaces:
    • ⛔ STOP, CONFIRM AT SITE SURVEY: The job description mentions confined spaces (e.g., small plant rooms, roof voids, underfloor voids). Entry into any confined space requires a specific safe system of work, including emergency rescue arrangements, under the Confined Spaces Regulations 1997. This is a legal precondition to entry. A separate risk assessment must be completed for any confined space work.
  6. Hot Works Permit: Obtain a hot works permit from the client/site management before commencing any soldering or brazing.
  7. Welfare: Provide hand-wash facilities with soap and warm water. A strict hygiene regime must be followed, with hands washed before eating, drinking, or smoking.

5d. Personal Protective Equipment (PPE) & Respiratory Protective Equipment (RPE)

PPE/RPE is a last resort and must be used in addition to the controls above. All PPE/RPE will be provided free of charge and must be maintained.

TaskRequired PPE / RPE (to specified standard)
All TasksSafety footwear (BS EN ISO 20345), Overalls.
Soldering / BrazingSafety glasses (BS EN 166), Heat-resistant gloves (BS EN 407).
Using Solvent CementChemical-resistant gloves (BS EN 374, Nitrile), Safety glasses (BS EN 166). RPE: ABEK1 filter respirator if ventilation is poor.
Drilling MasonryRPE: FFP3 disposable mask or half-mask with P3 filter (BS EN 149 / BS EN 140). RPE users must be face-fit tested. Safety glasses (BS EN 166), Hearing protection (BS EN 352).
Handling Flux / SealantsBarrier cream and suitable gloves (e.g. Nitrile).
Draining Down SystemsWaterproof gloves, Safety glasses (BS EN 166).

6. Action Plan to Implement Controls

Action RequiredResponsible PersonCompleted, date & initials
Obtain and review the Safety Data Sheets for all products being taken to site.A. Supervisor
Confirm site asbestos register has been checked and is clear for planned work locations.A. Supervisor
Develop a specific Safe System of Work if any entry to a confined space is required.A. Supervisor
Ensure M-Class (or higher) on-tool dust extraction is available and used for all masonry drilling.A. Supervisor
Confirm all gas engineers hold current Gas Safe registration for the work scope.A. Supervisor
Confirm personal CO alarms are in-date, calibrated and used by all operatives.A. Supervisor
Brief all operatives on the findings of this COSHH assessment and the required controls.A. Supervisor

7. Exposure vs WEL

With the engineering and administrative controls fully implemented, exposure levels for all substances are expected to be controlled well below their Workplace Exposure Limits. For substances without a WEL and for all sensitisers/carcinogens (rosin, silica), exposure will be reduced to as low as is reasonably practicable (ALARP).

8. First Aid

  • Eyes: Immediately flush with copious amounts of clean water for at least 15 minutes. Seek medical attention.
  • Skin: Remove contaminated clothing. Wash affected area thoroughly with soap and water. For flux burns, seek immediate medical attention.
  • Inhalation: Remove person to fresh air. If they feel unwell, seek medical attention. For gas/CO exposure, follow emergency procedures.
  • Ingestion: Do not induce vomiting. Wash out mouth with water and seek immediate medical attention.
  • A suitably stocked first aid kit and a trained first aider will be available. The site first aid provisions will be identified during induction.

9. Spillage & Accidental Release

  • Minor Spills (Solvents/Sealants): Ventilate the area. Contain the spill with sand, earth or proprietary absorbent granules. Prevent entry into drains. Scoop up into a suitable container for disposal.
  • Gas Leak: Extinguish all naked flames. Do not operate electrical switches. Isolate the gas supply at the meter. Ventilate the area. Evacuate non-essential personnel. Contact the National Gas Emergency Service.

10. Handling, Storage & Disposal

  • All substances will be stored in their original, clearly labelled containers.
  • Flammable substances (e.g. solvent cement) will be kept away from ignition sources and stored in a secure, well-ventilated location.
  • Waste materials (empty containers, used rags, sealant tubes) will be segregated and disposed of in accordance with the Control of Pollution Act 1974 and Hazardous Waste Regulations 2005 via a licensed waste carrier.

11. Health Surveillance

No routine health surveillance is required for this short-duration work. However, if an operative reports respiratory or skin symptoms that may be work-related, they must report this to their supervisor immediately for referral to an occupational health specialist. This is a requirement under COSHH Regulation 11.

12. Information, Instruction & Training

All operatives have been instructed on the hazards of the substances in use, the findings of this assessment, and the control measures they must use. Safety Data Sheets for all products are available on site for reference. All gas engineers are trained and accredited via the Gas Safe Register scheme. Operatives using RPE are face-fit tested and trained in its correct use.

13. Review

This assessment shall be reviewed by 14 October 2027, or sooner if there is a significant change to the substances used, the work process, the location, or if it is suspected that the control measures are no longer effective.


Declaration and Sign-off

The responsible person confirms that the required actions in Section 6 have been completed and the control measures detailed in this assessment have been implemented and are in place. All operatives have been briefed on and understand this assessment.

NameRoleSignatureDate
A. SupervisorSupervisor
Operative 1
Operative 2
Operative 3

What a compliant COSHH Assessment must contain

  • Each substance with its hazard statements and CAS number from the SDS
  • The Workplace Exposure Limit (EH40) where one exists, never invented
  • Controls in order of effectiveness, LEV and ventilation before RPE (COSHH 2002)
  • Process-generated substances screened (dust, fume, silica)

Why a commercial catering engineer's COSHH Assessment gets rejected

  • Generic solvent boilerplate instead of the actual SDS hazards
  • A Workplace Exposure Limit fabricated for a substance that has none
  • Exposure risk credited mainly to gloves/masks (RPE is the LAST resort)
  • Process dust/fume (wood dust, welding fume, RCS) not assessed

Already have one? Check it against the standard, free.

Paste it below and it is scored the way an inspector would, with the failings that would get it rejected. No sign-up.

Commercial Catering Engineers hazards it must cover

Typical commercial catering engineer work, meaning Install, service, repair and commission commercial catering equipment including gas appliances, electrical cooking equipment, refrigeration units and extraction systems in kitchens., brings hazards a COSHH Assessment has to address:

  • Gas at work: uncontrolled release or ignition during work on commercial gas appliances
  • Carbon monoxide accumulation from incomplete combustion during commissioning and fault-finding
  • Electrical hazards from hardwired three-phase cooking equipment and interlock systems
  • Grease-laden extraction ductwork: fire risk and hazardous residue during inspection or repair
  • Hot surfaces, scalding fluids and steam from equipment under service in live kitchens
  • Legionella risk in water-cooled equipment and condensate systems

Generate your COSHH Assessment in minutes

Built to the correct published standard for a commercial catering engineer: specific controls, the right legal basis, a review date and a sign-off section you can operate.

Start your COSHH Assessment

FAQ

Do commercial catering engineers legally need a COSHH Assessment?

A COSHH assessment of the hazardous substances used or created, built from the product's Safety Data Sheet (COSHH 2002). For commercial catering engineer work, meaning Install, service, repair and commission commercial catering equipment including gas appliances, electrical cooking equipment, refrigeration units and extraction systems in kitchens., it is the document a client, principal contractor or inspector expects to see, grounded in COSHH 2002 reg 6/7 (HSE), built from the product Safety Data Sheet.

What must a commercial catering engineer's COSHH Assessment contain?

At minimum: each substance with its hazard statements and CAS number from the SDS; the Workplace Exposure Limit (EH40) where one exists, never invented; controls in order of effectiveness, LEV and ventilation before RPE (COSHH 2002); process-generated substances screened (dust, fume, silica).

Why does a commercial catering engineer's COSHH Assessment get rejected?

The usual reasons: generic solvent boilerplate instead of the actual SDS hazards; A Workplace Exposure Limit fabricated for a substance that has none; exposure risk credited mainly to gloves/masks (RPE is the LAST resort); process dust/fume (wood dust, welding fume, RCS) not assessed.

Which regulation is a commercial catering engineer's COSHH Assessment written under?

COSHH 2002. The full text is on legislation.gov.uk at https://www.legislation.gov.uk/uksi/2002/2677/contents.

How fast can I get a COSHH Assessment?

A couple of minutes. Describe the job, and RAMSReady writes a COSHH Assessment for your exact commercial catering engineer job live against the correct standard, with a review date and a sign-off/records section.

Not writing this one today?

We will email you a one page overview of what RAMSReady covers, so you have it when you need it.

Want to see how it would work for your firm?

Tell us roughly what you run and who keeps your records, and we will come back to you.

Related guides

Other documents for Commercial Catering Engineers

Similar trades

Templates and tools